Environmental RoomsWe offer models of controlled environmental rooms that are manufactured from the highest quality materials and are well insulated for maximum uniformity of temperature and humidity. They feature user-friendly microprocessor controls for optimum accuracy and are available in single temperature setpoint or multi-temperature styles and a wide range of sizes for almost any controlled environmental application. The Modular Environmental Rooms are constructed from either galvanized steel, stainless steel or aluminum. Four inch, foamed-in-place urethane insulated walls give you the energy effiencey and built-in strength over conventional type materials. It has twice the insulating value of styrene. It is strong rigid, will not sag or mat, is impervious to moisture, vermin and odor proof. Panel Fabrication: Standard wall, ceiling and floor panels shall be 11-1/2", 23", 34-1/2" and 46" in width and shall be interchangeable with the like panels. Standard heights of walk-ins with floors shall be 8'-5", 9'-5" and 10'-5". Corner panels shall be 90 degree angles with 12" exterior horizontal measurements. Available standard heights without floors, with PVC Screeds are 8'-1", 8'-5", 9'-1", 9'-5", 10'-1", 10'-5". Panels shall consist of "foamed-in-place" urethane insulation sandwiched between interior and exterior metal "skin" which has been die-formed and gauged for uniformity in size. Edges of panels shall be "foamed-in-place" tongue and groove with locking facilities "foamed-in-place" at time of fabrication. Floor Construction: A. Floor Type: Panels shall be fabricated with 16 gauge stainless steel, designed to readily withstand uniformity-distributed loads of 600 lbs. Per square foot. B. Floorless: Provide thermally effective PVC floor screeds. Screeds will be designed to hug floor surface and terminated in a coved radius at both interior and exterior floor joint, Flat-Bottomed Walls are also available and will sit directly on the floor surface. SIZES: Standard and custom from small step-ins to large drive-ins; modular design allows customer to determine the best fit. REFRIGERATION: Semi-hermetic or hermetic condensing units use minimum energy and maximum control stabilities; NON-CFC Refrigerants are available as an option. Five-year warranties are available. Condensing units and evaporator units are available either air-cooled or water-cooled configurations. Airmont offers internal evaporator/blower or remote air handling systems. All systems utilize solid state control valves to precisely control the room temperature. Redundant conditioning systems with automatic switchover can be supplied for critical applications.
Environmental Room Standard Specifications:
Baked on white enamel front exterior and interior Home - About - Contact - Products - Environmental Room - Growth Room - Warm Room - Incubator Room - Insect Rearing Room - Tissue Culture Room - Cold Room - Laminar Air Flow Room - 4 Degree Celsius Room - Clean Room - Negative Pressure Isolation Room - Tuberculosis (TB) Isolation Room - Positive Pressure Isolation Room - Electron-Microscope / Microscopy Room - Controls - |
Call Us: 845-357-3062 info@airmontinc.com [Email this page] |